← 返回

Guidelines for the Intraprocedural Imaging for Mitral Valve Transcatheter Edge-to-Edge Repair (M-TEER): Recommendations from the American Society of Echocardiography.

Guidelines for the Intraprocedural Imaging for Mitral Valve Transcatheter Edge-to-Edge Repair (M-TEER): Recommendations from the American Society of Echocardiography.

期刊: Journal of the American Society of Echocardiography : official publication of the American Society o 日期: 2026-06-01 PMID: 42242827 DOI: 10.1016/j.echo.2026.03.003 浏览: 50
作者: Little SH, Quader N, Brady M, Dillenbeck A, Garcia-Sayan E, Jain R, Mackensen GB, Price MJ, Saric M, Scalia GM
SH, L., N, Q., M, B., A, D., E, G.S., R, J., GB, M., MJ, P., M, S., & GM, S. (2026). Guidelines for the Intraprocedural Imaging for Mitral Valve Transcatheter Edge-to-Edge Repair (M-TEER): Recommendations from the American Society of Echocardiography.. Journal of the American Society of Echocardiography : official publication of the American Society o. https://doi.org/10.1016/j.echo.2026.03.003
SH L, N Q, M B, A D, E GS, R J, et al. Guidelines for the Intraprocedural Imaging for Mitral Valve Transcatheter Edge-to-Edge Repair (M-TEER): Recommendations from the American Society of Echocardiography.. Journal of the American Society of Echocardiography : official publication of the American Society o. 2026; doi: 10.1016/j.echo.2026.03.003
SH L, N Q, M B, et al. Guidelines for the Intraprocedural Imaging for Mitral Valve Transcatheter Edge-to-Edge Repair (M-TEER): Recommendations from the American Society of Echocardiography.[J]. Journal of the American Society of Echocardiography : official publication of the American Society o. 2026. DOI: 10.1016/j.echo.2026.03.003.
@article{sh2026,
  author = {Little SH and Quader N and Brady M and Dillenbeck A and Garcia-Sayan E and Jain R and Mackensen GB and Price MJ and Saric M and Scalia GM},
  title = {Guidelines for the Intraprocedural Imaging for Mitral Valve Transcatheter Edge-to-Edge Repair (M-TEER): Recommendations from the American Society of Echocardiography.},
  journal = {Journal of the American Society of Echocardiography : official publication of the American Society o},
  year = {2026},
  doi = {10.1016/j.echo.2026.03.003},
  note = {PMID: 42242827},
}
TY  - JOUR
AU  - Little SH
AU  - Quader N
AU  - Brady M
AU  - Dillenbeck A
AU  - Garcia-Sayan E
AU  - Jain R
AU  - Mackensen GB
AU  - Price MJ
AU  - Saric M
AU  - Scalia GM
TI  - Guidelines for the Intraprocedural Imaging for Mitral Valve Transcatheter Edge-to-Edge Repair (M-TEER): Recommendations from the American Society of Echocardiography.
T2  - Journal of the American Society of Echocardiography : official publication of the American Society o
PY  - 2026
DO  - 10.1016/j.echo.2026.03.003
AN  - PMID:42242827
ER  - 

摘要

As the number of mitral valve transcatheter edge-to-edge repair procedures increases, there are catheter operators and interventional echocardiography operators performing these procedures with variable expertise. Expert imaging is paramount for the success of these procedures and requires knowledge of mitral valve anatomy, the ability to quickly manipulate two-dimensional (2D) and three-dimensional (3D) images in real time, and sufficient procedural experience to anticipate challenges and offer imaging solutions. There are currently no standard algorithms for the interventional echocardiographer to direct a successful mitral valve transcatheter edge-to-edge repair procedure. This guideline sets forth imaging views and the standard procedural steps and defines the imaging content that must be communicated using 2D, biplane, 3D volume, and/or multiplanar reconstruction 3D formats.

AI 智能解读

相关文献

返回分类: 心脏瓣膜 查看原文 (DOI)