Progressive reduction in complications of cryoballoon pulmonary vein isolation for atrial fibrillation.
📚 期刊: Journal of cardiovascular medicine (Hagerstown, Md.)📅 发表: 0000-00-00🔬 PMID: 42349391🔗 DOI:10.2459/JCM.0000000000001886👁️ 浏览: 17
👤 作者: Bertaglia E, Arena G, Tondo C, Molon G, Pieragnoli P, Mitacchione G, Manfrin M, Perego G, Rordorf R, Ricciardi D
房颤
📑 引用格式
APAVancouver国标 GB/T 7714BibTeXRIS
Bertaglia E, Arena G, Tondo C, Molon G, Pieragnoli P, Mitacchione G, Manfrin M, Perego G, Rordorf R, Ricciardi D (0000). Progressive reduction in complications of cryoballoon pulmonary vein isolation for atrial fibrillation.. Journal of cardiovascular medicine (Hagerstown, Md.). https://doi.org/10.2459/JCM.0000000000001886
🔗 分享文献
📝 摘要
AIMS: Cryoballoon pulmonary vein isolation (CB-PVI) has become an established treatment for atrial fibrillation and, recently, it has been proposed as first-line therapy for the treatment of paroxysmal atrial fibrillation. Nevertheless, some concerns remain regarding the safety of this thermal energy-based approach. This prospective analysis aimed to assess the procedural complication rate of CB-PVI in a large cohort of consecutive patients over a nearly 13-year period. METHODS: Data from consecutive patients treated with CB-PVI for atrial fibrillation between April 2012 and November 2024 in 35 institutions were analyzed. All complications occurring from patient admission up to 3 months postprocedure were recorded. RESULTS: Eight thousand five hundred and thirty-one patients were enrolled (27.2% women, mean age 60.8 ± 10.5 years, 75.7% with paroxysmal atrial fibrillation), and 211 of them (2.49%) experienced at least one procedural adverse event related to CB-PVI. Of note, one cardiac tamponade event led to a sudden cardiovascular death (0.01%). A statistically significant reduction in complication rates was observed amongst three cohorts of product usage: from 2012 to 2015 ( n = 1326 patients, 5.0%), from 2016 to 2019 ( n = 3487 patients, 2.5%), and from 2020 to 2024 ( n = 3718 patients, 1.6%; P < 0.001). Multivariate logistic regression analysis identified use of the Arctic Front Advance PRO balloon as a significant protective factor against complications [OR 0.26 (0.17-0.40), P < 0.001], whereas female sex emerged as the strongest predictor of adverse events [OR 1.54 (1.11-2.13), P < 0.01]. CONCLUSION: CB-PVI for atrial fibrillation ablation has proven to be a well tolerated procedure, with a steadily decreasing complication rate over time.