← 返回

Smart Technology, Fragile Hearts: Navigating AI's Challenges and Limitations in Heart Failure Management.

Smart Technology, Fragile Hearts: Navigating AI's Challenges and Limitations in Heart Failure Management.

期刊: Current heart failure reports 日期: 2026-06-15 PMID: 42295460 DOI: 10.1007/s11897-026-00766-9 浏览: 39
作者: Nona P, Firos JB, Zografos C, Schuuring MJ, Bhatt A, Andrikopoulou E
P, N., JB, F., C, Z., MJ, S., A, B., & E, A. (2026). Smart Technology, Fragile Hearts: Navigating AI's Challenges and Limitations in Heart Failure Management.. Current heart failure reports. https://doi.org/10.1007/s11897-026-00766-9
P N, JB F, C Z, MJ S, A B, E A. Smart Technology, Fragile Hearts: Navigating AI's Challenges and Limitations in Heart Failure Management.. Current heart failure reports. 2026; doi: 10.1007/s11897-026-00766-9
P N, JB F, C Z, et al. Smart Technology, Fragile Hearts: Navigating AI's Challenges and Limitations in Heart Failure Management.[J]. Current heart failure reports. 2026. DOI: 10.1007/s11897-026-00766-9.
@article{p2026,
  author = {Nona P and Firos JB and Zografos C and Schuuring MJ and Bhatt A and Andrikopoulou E},
  title = {Smart Technology, Fragile Hearts: Navigating AI's Challenges and Limitations in Heart Failure Management.},
  journal = {Current heart failure reports},
  year = {2026},
  doi = {10.1007/s11897-026-00766-9},
  note = {PMID: 42295460},
}
TY  - JOUR
AU  - Nona P
AU  - Firos JB
AU  - Zografos C
AU  - Schuuring MJ
AU  - Bhatt A
AU  - Andrikopoulou E
TI  - Smart Technology, Fragile Hearts: Navigating AI's Challenges and Limitations in Heart Failure Management.
T2  - Current heart failure reports
PY  - 2026
DO  - 10.1007/s11897-026-00766-9
AN  - PMID:42295460
ER  - 

摘要

PURPOSE OF REVIEW: This review synthesizes recent progress in applications of artificial intelligence to heart failure care, including phenotyping, risk stratification, imaging interpretation, and point-of-care decision support, and delineates barriers that currently limit safe and equitable clinical translation. RECENT FINDINGS: Clinical datasets remain heterogeneous and incomplete; fragmentation across electronic records, telemetry, and imaging repositories constrains generalizability and external validity. Underrepresentation of key subgroups and outcome misclassification introduce systematic error that can widen disparities. Performance drifts as therapies and workflows evolve, yet monitoring after deployment is uncommon. Model opacity hinders error analysis and clinician trust. Regulatory and data-sharing frameworks are evolving and inconsistent, complicating multisite validation and ongoing surveillance. Mitigation strategies with the strongest support include rigorous cohort curation; transparent reporting; geographic and temporal external validation; prospective pilots with prespecified safety checks; bias auditing with equity metrics; concise documentation such as model cards and factsheets; continuous monitoring with clear contingency and rollback plans; and human oversight embedded throughout governance. Embedding safeguards into development and implementation can enable AI to deliver measurable value in heart failure care while protecting patient safety and equity. Immediate priorities are robust evaluation, routine surveillance for drift and harm, and alignment with outcomes that matter to patients.

AI 智能解读

相关文献

返回分类: 心衰 查看原文 (DOI)
已选择 0 篇文献