← 返回

Haemolysis and renal effects across pulsed field ablation systems in atrial fibrillation.

Haemolysis and renal effects across pulsed field ablation systems in atrial fibrillation.

期刊: Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working grou 日期: 2026-08-04 PMID: 42530033 DOI: 10.1093/europace/euag190 浏览: 24
作者: Rocchetti M, Schaack D, Marrese A, Urbani A, Kheir J, Najafi S, Gunawardene M, Marx A, Lurz J, Schmidt B
M, R., D, S., A, M., A, U., J, K., S, N., M, G., A, M., J, L., & B, S. (2026). Haemolysis and renal effects across pulsed field ablation systems in atrial fibrillation.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working grou. https://doi.org/10.1093/europace/euag190
M R, D S, A M, A U, J K, S N, et al. Haemolysis and renal effects across pulsed field ablation systems in atrial fibrillation.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working grou. 2026; doi: 10.1093/europace/euag190
M R, D S, A M, et al. Haemolysis and renal effects across pulsed field ablation systems in atrial fibrillation.[J]. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working grou. 2026. DOI: 10.1093/europace/euag190.
@article{m2026,
  author = {Rocchetti M and Schaack D and Marrese A and Urbani A and Kheir J and Najafi S and Gunawardene M and Marx A and Lurz J and Schmidt B},
  title = {Haemolysis and renal effects across pulsed field ablation systems in atrial fibrillation.},
  journal = {Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working grou},
  year = {2026},
  doi = {10.1093/europace/euag190},
  note = {PMID: 42530033},
}
TY  - JOUR
AU  - Rocchetti M
AU  - Schaack D
AU  - Marrese A
AU  - Urbani A
AU  - Kheir J
AU  - Najafi S
AU  - Gunawardene M
AU  - Marx A
AU  - Lurz J
AU  - Schmidt B
TI  - Haemolysis and renal effects across pulsed field ablation systems in atrial fibrillation.
T2  - Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working grou
PY  - 2026
DO  - 10.1093/europace/euag190
AN  - PMID:42530033
ER  - 

摘要

AIMS: Pulsed field ablation (PFA) is a non-thermal energy modality for ablation of atrial fibrillation (AF). Although PFA has demonstrated an excellent overall safety profile, increasing evidence suggests an association with intravascular haemolysis, and acute kidney injury (AKI). However, the extent of haemolysis across different PFA catheters remains poorly characterized and warrants further investigation. METHODS AND RESULTS: We prospectively enrolled 239 patients undergoing AF ablation using the pentaspline (n = 107), balloon-in-basket (n = 71), or lattice-tip (n = 61) catheter. Laboratory markers of haemolysis, myocardial injury, renal function and haemoglobin were collected pre- and 24h post-procedure. Significant haptoglobin depletion was observed exclusively with pentaspline, [pre 99.8 mg/dL (70.2-122) vs. post 55.7 mg/dL (23.2-91.8); P < 0.001] Reductions with the lattice-tip (P = 0.074) and the balloon-in-basket (P = 0.201) catheter did not reach statistical significance. AKI was only observed with the pentaspline catheter (pentaspline: 4.9%; balloon-in-basket: 0.0%; lattice tip: 0.0%; P = 0.020). Myocardial markers increased across all groups, but significantly higher in pentaspline and balloon-in-basket (P = n.s.) vs. lattice-tip (P < 0.001 vs. pentaspline, P < 0.001 vs. balloon in basket). CONCLUSION: In this large cohort, contemporary PFA systems appear safe but catheter design influences the extent of haemolysis, AKI, and myocardial injury. The pentaspline catheter was associated with the greatest haemolytic effect and higher transient AKI, without clinically relevant reductions in haemoglobin or persistent renal impairment. Higher levels of myocardial injury in the pentaspline and balloon-in-basket groups correspond to the larger lesion footprints of these devices.

AI 智能解读

相关文献

返回分类: 心律失常 查看原文 (DOI)
已选择 0 篇文献