← 返回

Prosthesis-patient mismatch with intra-annular self-expanding valves: an analysis of the PORTICO IDE trial.

Prosthesis-patient mismatch with intra-annular self-expanding valves: an analysis of the PORTICO IDE trial.

期刊: EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Card 日期: 2026-07-06 PMID: 42405628 DOI: 10.4244/EIJ-D-26-00158 浏览: 33
作者: Fontana GP, Waksman R, Salemi A, Cohen M, Abernethy W, Hermiller J, Baker C, Montarello J, Kleiman N, Sondergaard L
GP, F., R, W., A, S., M, C., W, A., J, H., C, B., J, M., N, K., & L, S. (2026). Prosthesis-patient mismatch with intra-annular self-expanding valves: an analysis of the PORTICO IDE trial.. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Card. https://doi.org/10.4244/EIJ-D-26-00158
GP F, R W, A S, M C, W A, J H, et al. Prosthesis-patient mismatch with intra-annular self-expanding valves: an analysis of the PORTICO IDE trial.. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Card. 2026; doi: 10.4244/EIJ-D-26-00158
GP F, R W, A S, et al. Prosthesis-patient mismatch with intra-annular self-expanding valves: an analysis of the PORTICO IDE trial.[J]. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Card. 2026. DOI: 10.4244/EIJ-D-26-00158.
@article{gp2026,
  author = {Fontana GP and Waksman R and Salemi A and Cohen M and Abernethy W and Hermiller J and Baker C and Montarello J and Kleiman N and Sondergaard L},
  title = {Prosthesis-patient mismatch with intra-annular self-expanding valves: an analysis of the PORTICO IDE trial.},
  journal = {EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Card},
  year = {2026},
  doi = {10.4244/EIJ-D-26-00158},
  note = {PMID: 42405628},
}
TY  - JOUR
AU  - Fontana GP
AU  - Waksman R
AU  - Salemi A
AU  - Cohen M
AU  - Abernethy W
AU  - Hermiller J
AU  - Baker C
AU  - Montarello J
AU  - Kleiman N
AU  - Sondergaard L
TI  - Prosthesis-patient mismatch with intra-annular self-expanding valves: an analysis of the PORTICO IDE trial.
T2  - EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Card
PY  - 2026
DO  - 10.4244/EIJ-D-26-00158
AN  - PMID:42405628
ER  - 

摘要

BACKGROUND: Aortic valve replacement in small aortic annuli is associated with an increased risk of impaired haemodynamics. AIMS: We sought to evaluate haemodynamic outcomes and prosthesis-patient mismatch (PPM) in aortic stenosis (AS) patients treated with Portico, Evolut, and SAPIEN 3 transcatheter aortic valves (TAVs) in small (diameter ≤23 mm) and large (diameter >23 mm) aortic annuli. METHODS: PORTICO IDE was a prospective, multicentre, international, premarket randomised controlled trial comparing Portico to Evolut and SAPIEN 3 TAVs. An independent core laboratory evaluated the mean transvalvular pressure gradient (MG) and the effective orifice area (EOA), and PPM was calculated based on the core lab results. RESULTS: A total of 675 patients with severe AS at high or extreme surgical risk were included (Portico: 362 patients; Evolut: 109; SAPIEN 3: 204). At 30 days, the EOA and rates of severe PPM in small aortic annuli were similar between Portico and Evolut (EOA 1.65 cm2 vs 1.78 cm2; p=0.09; PPM 3.3% vs 3.0%; p=1.0) with a higher MG (8.5 mmHg vs 6.9 mmHg; p=0.034) for Portico. No significant differences were observed between Portico and Evolut for large aortic annuli (MG 8.3 mmHg vs 7.4 mmHg; p=0.069; EOA 1.93 cm2 vs 2.02 cm2; p=0.18; PPM 5.4% vs 3.2%; p=0.83). Portico was superior to SAPIEN 3 in both small (MG 8.5 mmHg vs 13.7 mmHg; p<0.0001; EOA 1.65 cm2 vs 1.40 cm2; p<0.0001; PPM 3.3% vs 26.3%; p<0.0001) and large annuli (MG 8.3 mmHg vs 10.9 mmHg; p<0.0001; EOA 1.93 cm2 vs 1.67 cm2; p<0.0001; PPM 5.4% vs 10.9%; p=0.0014). At 5 years, the rate of structural valve deterioration in patients with small aortic annuli was significantly lower in patients treated with Portico (2.2%) versus SAPIEN 3 (13.9%; p=0.03). CONCLUSIONS: Haemodynamic performance was similar for the intra-annular Portico and supra-annular Evolut. Portico haemodynamics outperformed the balloon-expandable SAPIEN 3 for PPM and mean gradient in both small and large aortic annuli.

AI 智能解读

相关文献

返回分类: 心血管 查看原文 (DOI)
已选择 0 篇文献