← 返回

Biocompatibility Assessment of a Hybrid Material Based on Epoxy-Treated Pericardium and Polyvinyl Alcohol Cryogel in a Rat Vascular and Subcutaneous Implantation Model.

Biocompatibility Assessment of a Hybrid Material Based on Epoxy-Treated Pericardium and Polyvinyl Alcohol Cryogel in a Rat Vascular and Subcutaneous Implantation Model.

期刊: Sovremennye tekhnologii v meditsine 日期: 2026-01-01 PMID: 42524404 DOI: 10.17691/stm2026.18.3.03 浏览: 10
作者: Ovcharenko EA, Glushkova TV, Senokosova EA, Klyshnikov KY, Akentieva TN, Klyueva AA, Mironov AV, Kostyunin AE
EA, O., TV, G., EA, S., KY, K., TN, A., AA, K., AV, M., & AE, K. (2026). Biocompatibility Assessment of a Hybrid Material Based on Epoxy-Treated Pericardium and Polyvinyl Alcohol Cryogel in a Rat Vascular and Subcutaneous Implantation Model.. Sovremennye tekhnologii v meditsine. https://doi.org/10.17691/stm2026.18.3.03
EA O, TV G, EA S, KY K, TN A, AA K, et al. Biocompatibility Assessment of a Hybrid Material Based on Epoxy-Treated Pericardium and Polyvinyl Alcohol Cryogel in a Rat Vascular and Subcutaneous Implantation Model.. Sovremennye tekhnologii v meditsine. 2026; doi: 10.17691/stm2026.18.3.03
EA O, TV G, EA S, et al. Biocompatibility Assessment of a Hybrid Material Based on Epoxy-Treated Pericardium and Polyvinyl Alcohol Cryogel in a Rat Vascular and Subcutaneous Implantation Model.[J]. Sovremennye tekhnologii v meditsine. 2026. DOI: 10.17691/stm2026.18.3.03.
@article{ea2026,
  author = {Ovcharenko EA and Glushkova TV and Senokosova EA and Klyshnikov KY and Akentieva TN and Klyueva AA and Mironov AV and Kostyunin AE},
  title = {Biocompatibility Assessment of a Hybrid Material Based on Epoxy-Treated Pericardium and Polyvinyl Alcohol Cryogel in a Rat Vascular and Subcutaneous Implantation Model.},
  journal = {Sovremennye tekhnologii v meditsine},
  year = {2026},
  doi = {10.17691/stm2026.18.3.03},
  note = {PMID: 42524404},
}
TY  - JOUR
AU  - Ovcharenko EA
AU  - Glushkova TV
AU  - Senokosova EA
AU  - Klyshnikov KY
AU  - Akentieva TN
AU  - Klyueva AA
AU  - Mironov AV
AU  - Kostyunin AE
TI  - Biocompatibility Assessment of a Hybrid Material Based on Epoxy-Treated Pericardium and Polyvinyl Alcohol Cryogel in a Rat Vascular and Subcutaneous Implantation Model.
T2  - Sovremennye tekhnologii v meditsine
PY  - 2026
DO  - 10.17691/stm2026.18.3.03
AN  - PMID:42524404
ER  - 

摘要

UNLABELLED: The aim of the study was to evaluate the biocompatibility of a hybrid material based on epoxy-treated bovine pericardium and cryostructured polyvinyl alcohol (PVA) after implantation into the rat aortic wall and subcutaneous tissue. MATERIALS AND METHODS: The study evaluated hybrid material patches based on epoxy-treated bovine pericardium and cryostructured PVA; unmodified "KemPeriplasNeo" pericardial patches served as controls. The samples were implanted into the abdominal aortic wall and subcutaneously in male Wistar rats. The vascular implantation periods were 5 and 20 days, and the subcutaneous implantation periods were 60 and 120 days. The specimens were excised from the aorta and studied histologically using Russell-Movat staining and immunostaining for neutrophil myeloperoxidase (MPO) and the macrophage marker CD68. The calcium content in subcutaneously implanted samples was assessed by spectrophotometry and alizarin red S staining. The quantitative data were presented as the median, percentiles, minimal and maximal values (Me [25%-75%; min-max]). RESULTS: After implantation into the abdominal aortic wall, the hybrid material samples showed a lower tendency toward thrombotic deposit formation on the surface compared to the pericardium. On day 5 of implantation, the thrombus thickness was 49.1 [34.7-64.6; 27.4-71.6] μm in the experimental group vs 170.3 [158.1-210.3; 124.4-217.0] μm in the controls (p<0.001). By day 20 of implantation, the macrophage density was lower in the peri-implant area of the modified samples compared to the controls: 219 [187-275; 112-362] vs 301 [244-338; 194-433] CD68+ cells per field of view (p<0.001), respectively. The neutrophil density at all experimental time points, as well as the macrophage density on day 5 of implantation did not differ significantly between the tested materials (p>0.17). No signs of calcification were detected in either group following the subcutaneous implantation over a period of 60 or 120 days. The control pericardium in the subcutaneous model showed the signs of cell-mediated degradation, whereas the hybrid samples were resistant to immune-cell infiltration and preserved their internal architecture. CONCLUSION: The modification of epoxy-treated bovine pericardium with cryostructured PVA cryogel improved its biocompatibility and enhanced resistance to biodegradation in a rat model after aortic-wall and subcutaneous implantation. The developed material may be used to create next-generation heart valve bioprostheses with potentially improved resistance to structural valve degeneration.

AI 智能解读

相关文献

返回分类: 心血管 查看原文 (DOI)
已选择 0 篇文献