← 返回

Electrophysiological Insights in a Successful Cavotricuspid Isthmus Ablation of an Atypical Denovo Single-Loop Clockwise Epicardial Biatrial Flutter.

Electrophysiological Insights in a Successful Cavotricuspid Isthmus Ablation of an Atypical Denovo Single-Loop Clockwise Epicardial Biatrial Flutter.

期刊: Cardiac electrophysiology clinics 日期: 2026-09-01 PMID: 42580790 DOI: 10.1016/j.ccep.2026.06.002 浏览: 9
作者: Adhikari U, Marimuthu S, Chandh Raja D
U, A., S, M., & D, C.R. (2026). Electrophysiological Insights in a Successful Cavotricuspid Isthmus Ablation of an Atypical Denovo Single-Loop Clockwise Epicardial Biatrial Flutter.. Cardiac electrophysiology clinics. https://doi.org/10.1016/j.ccep.2026.06.002
U A, S M, D CR. Electrophysiological Insights in a Successful Cavotricuspid Isthmus Ablation of an Atypical Denovo Single-Loop Clockwise Epicardial Biatrial Flutter.. Cardiac electrophysiology clinics. 2026; doi: 10.1016/j.ccep.2026.06.002
U A, S M, D CR. Electrophysiological Insights in a Successful Cavotricuspid Isthmus Ablation of an Atypical Denovo Single-Loop Clockwise Epicardial Biatrial Flutter.[J]. Cardiac electrophysiology clinics. 2026. DOI: 10.1016/j.ccep.2026.06.002.
@article{u2026,
  author = {Adhikari U and Marimuthu S and Chandh Raja D},
  title = {Electrophysiological Insights in a Successful Cavotricuspid Isthmus Ablation of an Atypical Denovo Single-Loop Clockwise Epicardial Biatrial Flutter.},
  journal = {Cardiac electrophysiology clinics},
  year = {2026},
  doi = {10.1016/j.ccep.2026.06.002},
  note = {PMID: 42580790},
}
TY  - JOUR
AU  - Adhikari U
AU  - Marimuthu S
AU  - Chandh Raja D
TI  - Electrophysiological Insights in a Successful Cavotricuspid Isthmus Ablation of an Atypical Denovo Single-Loop Clockwise Epicardial Biatrial Flutter.
T2  - Cardiac electrophysiology clinics
PY  - 2026
DO  - 10.1016/j.ccep.2026.06.002
AN  - PMID:42580790
ER  - 

摘要

Biatrial macro-reentrant tachycardias are rare in patients without prior atrial intervention and often pose diagnostic and therapeutic challenges. We present a case of de novo single-loop biatrial flutter in a structurally normal heart, in which high-density mapping was critical to understanding the reentrant circuit. Initial attempts at ablation in the left atrium were unsuccessful. Successful entrainment could be demonstrated from both the lateral mitral annulus and cavotricuspid isthmus. Ablation at the cavotricuspid isthmus resulted in termination with durable success. This case highlights the importance of reassessing the mechanism when attempts at ablation fail to modify tachycardia and reinforce CTI as a critical substrate even in complex biatrial activation patterns.

AI 智能解读

相关文献

返回分类: 心血管 查看原文 (DOI)
已选择 0 篇文献