← 返回

Impact of Reverse Dipper and Non-Dipper Blood Pressure Patterns on Myocardial Performance Index in Hypertensive Patients.

Impact of Reverse Dipper and Non-Dipper Blood Pressure Patterns on Myocardial Performance Index in Hypertensive Patients.

期刊: Echocardiography (Mount Kisco, N.Y.) 日期: 2026-06-01 PMID: 42223157 DOI: 10.1111/echo.70521 浏览: 32
作者: Aktan A, Kılıç R, Güzel T, Söner S, Aslan B, Demir M, Md AE, Arpa A, Coşkun MS, Tanırcan MR
A, A., R, K., T, G., S, S., B, A., M, D., AE, M., A, A., MS, C., & MR, T. (2026). Impact of Reverse Dipper and Non-Dipper Blood Pressure Patterns on Myocardial Performance Index in Hypertensive Patients.. Echocardiography (Mount Kisco, N.Y.). https://doi.org/10.1111/echo.70521
A A, R K, T G, S S, B A, M D, et al. Impact of Reverse Dipper and Non-Dipper Blood Pressure Patterns on Myocardial Performance Index in Hypertensive Patients.. Echocardiography (Mount Kisco, N.Y.). 2026; doi: 10.1111/echo.70521
A A, R K, T G, et al. Impact of Reverse Dipper and Non-Dipper Blood Pressure Patterns on Myocardial Performance Index in Hypertensive Patients.[J]. Echocardiography (Mount Kisco, N.Y.). 2026. DOI: 10.1111/echo.70521.
@article{a2026,
  author = {Aktan A and Kılıç R and Güzel T and Söner S and Aslan B and Demir M and Md AE and Arpa A and Coşkun MS and Tanırcan MR},
  title = {Impact of Reverse Dipper and Non-Dipper Blood Pressure Patterns on Myocardial Performance Index in Hypertensive Patients.},
  journal = {Echocardiography (Mount Kisco, N.Y.)},
  year = {2026},
  doi = {10.1111/echo.70521},
  note = {PMID: 42223157},
}
TY  - JOUR
AU  - Aktan A
AU  - Kılıç R
AU  - Güzel T
AU  - Söner S
AU  - Aslan B
AU  - Demir M
AU  - Md AE
AU  - Arpa A
AU  - Coşkun MS
AU  - Tanırcan MR
TI  - Impact of Reverse Dipper and Non-Dipper Blood Pressure Patterns on Myocardial Performance Index in Hypertensive Patients.
T2  - Echocardiography (Mount Kisco, N.Y.)
PY  - 2026
DO  - 10.1111/echo.70521
AN  - PMID:42223157
ER  - 

摘要

BACKGROUND: Abnormal nocturnal blood pressure patterns are associated with subclinical cardiac dysfunction in hypertension (HT). However, their relationship with the myocardial performance index (MPI) is not well-defined. METHODS: This retrospective study included 196 hypertensive patients who underwent 24-h ambulatory blood pressure monitoring (ABPM). Patients were classified as dipper, non-dipper, and reverse dipper according to nocturnal systolic blood pressure variation. Echocardiographic parameters, including MPI, were compared. Multivariate linear regression analysis was performed. RESULTS: The highest MPI values were found in the reverse dipper group (p < 0.001). Reverse dipper (B = 0.054, p < 0.001) and non-dipper (B = 0.023, p = 0.002) patterns were independently associated with increased MPI. MPI showed moderate discriminatory power in predicting the reverse dipper pattern (area under the curve [AUC] = 0.693). CONCLUSION: Reverse dipper and non-dipper patterns are associated with increased MPI. This finding suggests an association between abnormal circadian blood pressure patterns and subclinical cardiac dysfunction. Further prospective studies are required to determine clinical relevance.

AI 智能解读

相关文献

返回分类: 高血压 查看原文 (DOI)
已选择 0 篇文献