Safety and Efficacy of Pulsed-Field Ablation With a Pentaspline Ablation Catheter Versus Cryoablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis.

Safety and Efficacy of Pulsed-Field Ablation With a Pentaspline Ablation Catheter Versus Cryoablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis.

期刊: Clinical cardiology 日期: 2026-09-01 PMID: 42669978 DOI: 10.1002/clc.70459 浏览: 10
作者: Cai Y, Chen H, Li MF, Xu YZ
Y, C., H, C., MF, L., & YZ, X. (2026). Safety and Efficacy of Pulsed-Field Ablation With a Pentaspline Ablation Catheter Versus Cryoablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis.. Clinical cardiology. https://doi.org/10.1002/clc.70459
Y C, H C, MF L, YZ X. Safety and Efficacy of Pulsed-Field Ablation With a Pentaspline Ablation Catheter Versus Cryoablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis.. Clinical cardiology. 2026; doi: 10.1002/clc.70459
Y C, H C, MF L, et al. Safety and Efficacy of Pulsed-Field Ablation With a Pentaspline Ablation Catheter Versus Cryoablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis.[J]. Clinical cardiology. 2026. DOI: 10.1002/clc.70459.
@article{y2026,
  author = {Cai Y and Chen H and Li MF and Xu YZ},
  title = {Safety and Efficacy of Pulsed-Field Ablation With a Pentaspline Ablation Catheter Versus Cryoablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis.},
  journal = {Clinical cardiology},
  year = {2026},
  doi = {10.1002/clc.70459},
  note = {PMID: 42669978},
}
TY  - JOUR
AU  - Cai Y
AU  - Chen H
AU  - Li MF
AU  - Xu YZ
TI  - Safety and Efficacy of Pulsed-Field Ablation With a Pentaspline Ablation Catheter Versus Cryoablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis.
T2  - Clinical cardiology
PY  - 2026
DO  - 10.1002/clc.70459
AN  - PMID:42669978
ER  - 

摘要

BACKGROUND: Pulsed-field ablation (PFA) is an emerging technology for atrial fibrillation (AF) ablation. However, there is few studies comparing the clinical advantages and disadvantages of PFA and cryoballoon ablation (CBA). This study aimed to perform a comprehensive meta-analysis to evaluate the efficacy and safety of PFA using a pentaspline ablation catheter compared with CBA for treating AF. METHODS: This study was registered in the International Prospective Register of Systematic Reviews (ID: CRD420251061599). Studies comparing PFA using a pentaspline ablation catheter with CBA for pulmonary vein isolation (PVI) were systematically searched from database inception to March 2025. RESULTS: Six trials involving 2024 patients were included. No significant difference was observed in atrial tachyarrhythmia recurrence between PFA and CBA (OR) = 0.71; 95% confidence interval (CI): 0.48 to 1.06). However, in patients with paroxysmal AF, the PFA group exhibited a lower incidence of AT recurrence (OR = 0.62; 95% CI: 0.46 to 0.85). PFA was superior to CBA in terms of ablation time (MD) = -14.12; 95% CI: -16.31 to -11.93) and left atrial dwell time (MD = -9.44; 95% CI: -15.69 to -3.19). Hypersensitive troponin release was higher in the PFA group (MD = 547.29; 95% CI: 53.55 to 1041.03), while CBA was associated with a higher incidence of phrenic nerve palsy (OR = 0.06; 95% CI: 0.01 to 0.30). CONCLUSION: PFA demonstrates superior safety and efficacy compared with CBA for PVI in patients with AF. These findings provide additional procedural options for patients and electrophysiologists in clinical practice.